Dell IDRAC6 1.95 Computer Drive User Manual


 
158 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgNicVLanEnable (Read/Write)
NOTE: For iDRAC6 Enterprise on Blade Servers, this object is read-only and VLAN
settings can be configured through CMC Web Interface. iDRAC6 displays only the
current VLAN settings and you cannot modify the settings from iDRAC6.
Shared with Failover All
LOMs
Enables teaming capabilities between all LOMs on the
host server integrated network interface controllers.
The remote access device network interface is fully
functional when the host operating system is configured
for NIC teaming. The remote access device receives data
through NIC 1 and NIC 2, but transmits data only
through NIC 1.
Failover occurs from NIC 2 to NIC 3 and then to NIC 4.
If NIC 4 fails, the remote access device fails over all data
transmission back to NIC 1, but only if the original NIC
1 failure has been corrected.
Description Enables or disables the VLAN capabilities of the RAC/BMC.
NOTE: For iDRAC6 Enterprise on Blade Servers, this object enables
or disables the VLAN capabilities of iDRAC6 from CMC.
All chassis management traffic, including the CMC and all
iDRACs, resides on this external VLAN when enabled. No iDRAC
configuration change is required to use this external management
network VLAN.
Legal Values 1 (TRUE)
0 (FALSE)
Default 0
Example racadm config -g cfgLanNetworking -o
cfgNicVLanEnable 1
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable 0
Table 3-2. cfgNicSelection Supported Modes
(continued)
Mode Description