254 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgAlertingSourceEmailName
Examples
racadm getconfig -g cfgAlerting -o
cfgAlertingEnable 1
racadm config -g cfgAlerting -o cfgAlertingEnable
1
Object value modified successfully.
cfgServerPowerSupply
This group is applicable only for iDRAC6 and contains information related to
the power supplies. The following sections provide information about the
objects in the cfgServerPowerSupply group.
NOTE: The cfgServerPowerSupply object group is applicable only for iDRAC6 on
Rack and Tower Servers and not for iDRAC6 Enterprise on Blade Servers.
NOTE: The getconfig subcommand always shows eight cfgServerPowerSupply
indexes, even if two power supplies are installed in the system or the system
supports a maximum of two power supply units. For the uninstalled and
unsupported units, all the objects in the cfgServerPowerSupply group displays a
value of 0.
cfgServerPowerSupplyIndex
NOTE: Indexes from 1 – 8 are supported to support up to 8 power supply units. If
any power supply unit is not present, cfgServerPowerSupplyOnlineStatus is absent
and for all the other properties, it is 0.
Description E-mail address used to send e-mail notifications when an event
occurs.
Legal Values None
Default None
Description Index of the power supply unit.
Legal Values Integer from 1-8
Default None