Dell IDRAC6 1.95 Computer Drive User Manual


 
58 RACADM Subcommand Details
Examples for CMC
Upload the firmware image from the TFTP server and start the firmware
update.
racadm fwupdate -g -u -a 192.168.0.100 -d
firmimg.cmc -m cmc-active
TFTP firmware update has been initiated. This
update process may take several minutes to
complete.
-m
<
modul
e>
NOTE: This option is applicable only for CMC.
Specifies the module or device to be updated. <module> is one of the
following values:
cmc-active
(default)
cmc-standby
kvm
server-n
where
n
= 1–16
server-generation
where generation = iDRAC or iDRAC6
iominf-n
where
n
= 1–6
NOTE: CMC version 3.00 accepts IPv4, IPv6, or fully qualified domain names
(FQDN) for both FTP and TFTP servers.
NOTE: You can specify the cmc-active and cmc-standby modules at
the same time along with one or more server-n modules. This enables the
devices to be updated together.
NOTE: See "Updating the IOM Infrastructure Device Firmware" section of the
"Using the CMC Web Interface" chapter of the Dell Chassis Management
Controller User Guide for additional information on the IOM infrastructure
device firmware update process.
When you use the
server-generation option, the CMC updates all
iDRACs of that particular generation that can be updated.
NOTE: Verify that the update applied to servers for a particular generation has
been validated for all impacted server models.
Table 2-11. fwupdate Subcommand Options
(continued)
Option Description