Dell IDRAC6 1.95 Computer Drive User Manual


 
48 RACADM Subcommand Details
Synopsis
racadm deploy -m <
module
> -u root -p <
password
> -s
<
ipaddress
> <
subnet
> <
gateway
> -b <
device
> -o <no|yes>
racadm deploy -m <
module
> -u root -p <
password
> -s -6
<
ipv6Address
> <
prefixlen
> <
gateway
> -b <
device
> -o <no|yes>
NOTE: <prefixlen> must be a number between 0 and 128.
racadm deploy -m <
module
> -u root -p <
password
> -d [-
6]
racadm deploy -a -u root -p <
password
>
Table 2-5 describes the deploy subcommand options.
Table 2-5. deploy Subcommand Options
Option Description
-b
<device> Specifies the first boot device; must be used with
-o.
Use with -m <module> to specify for a individual
server, or with -a for all servers
Legal values: device=None, PXE, HDD, CD-
DVD, vFDD, vCD-DVD, iSCSI, SD, FDD
-o
<no|yes> Indicates if the server should boot from the
device once; must be used with
-o.
Use with -m <module> to specify for a individual
server, or with -a for all servers
-a Creates and enables an iDRAC root user if it does
not already exist, and is executed on all the
existing servers in the chassis
-u root Indicates that the <password> is supplied for the
root user on the server. root is a constant
parameter, the only value that is valid with the -u
option.
-m
<module> Specifies the server you want to configure.
Legal values: server-n, where n=1–16
-p <password> Specifies the password for the root user on the
server.