Dell MD3220 Computer Accessories User Manual


 
Troubleshooting: Your Array 259
Troubleshooting Array and Expansion Enclosure
Connections
1
Verify that the RAID controller module port link status LED and the
RAID controller module status LED are solid green for each port that is
connected to a cable. If the LEDs are not solid green, see "Planning: RAID
Controller Modules" on page 31.
2
Ensure that all the cables are attached correctly according to array mode
you selected.
3
Turn off the server, storage array, and expansion enclosures.
4
Reseat the RAID controller module and reconnect cables on the storage
array and the server.
5
Turn on the expansion arrays and then the storage array and wait until the
system is fully booted.
6
Turn on the server.
7
Check the link status LED. If the link status LED is not green, replace the
cables.
If the problem is not resolved, see "Getting Help" on page 265.
8
Reboot the host server.
NOTE: You must turn off the host server before resetting the cables on
the storage array or expansion enclosure.
If the problem is not resolved, see "Getting Help" on page 265.
book.book Page 259 Tuesday, September 27, 2011 3:25 PM