Dell MD3220 Computer Accessories User Manual


 
Planning: About Your Storage Array 29
Power Supply and Cooling Fan Features
The MD3200 Series storage array includes two integrated, hot-swappable
power supply/cooling fan modules. Both modules must be installed to ensure
proper cooling. The system requires at least one of the cooling fans to
function to avoid overheating.
A power supply/cooling fan module can be replaced without powering down
the system. For information on removing and installing the modules, see
"Power Supply/Cooling Fan Module" on page 216.
CAUTION: A power supply/cooling fan module can be removed from a powered-
on enclosure for a maximum period of 5 minutes. Beyond that time, the system may
automatically shut down to prevent damage.
Drive-Status Indicator Pattern Condition
Off The physical disk is:
not yet discovered by the host server
•is spun down for removal
not supported for the RAID controller
module or is not in the physical disk slot
NOTE: The drive status indicator remains
off until all hard drives are initialized
after system power is turned on.
Drives are not ready for insertion or
removal during this time.
Steady green Physical disk is online
Green flashing (On 250 ms, Off 250 ms) Physical disk is being identified
Green flashing (On 400 ms, Off 100 ms) Physical disk rebuilding
Amber flashing (On 150 ms, Off 150 ms) Physical disk failed
Flashing green, amber, and Off (green On
500 ms, amber On 500 ms, Off 1000 ms)
Physical disk failure predicted (SMART)
Flashing green, amber, and Off (green 3
seconds, amber 3 seconds, and Off 3
seconds)
Physical disk rebuild aborted
book.book Page 29 Tuesday, September 27, 2011 3:25 PM