Dell R610 Server User Manual


 
24 About Your System
To resolve the problem and remove the LCD message, refer to the corrective
actions in the following table.
NOTE: The following LCD status messages are displayed in the Simple format. See
“Setup Menu“to select the format in which the messages are displayed.
Table 1-1. LCD Status Messages
Code Text Cause Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
If the problem persists,
see "Getting Help."
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature has a
reached a point outside of
the allowed range.
See "Troubleshooting
System Cooling
Problems."
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems."
If the problem persists,
see "Getting Help."
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing or
the voltage is outside of the
allowable range.
See "Troubleshooting the
System Battery."
E1211 RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "Installing
a RAID Battery" and
"Troubleshooting System
Cooling Problems."