Dell R610 Server User Manual


 
34 About Your System
E201B Keyboard
Controller
error. Power
cycle AC.
Keyboard controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201C SMI
initializatio
n failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201D Shutdown test
failure.
Power cycle
AC.
BIOS shutdown test failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory."
If the problem persists,
see "Getting Help."
E2020 CPU
configuration
failure.
Check screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting the
Processors."
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
Incorrect memory
configuration.
Check screen for specific
error messages (see
"Troubleshooting System
Memory").
E2022 General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
Table 1-1. LCD Status Messages (continued)
Code Text Cause Corrective Actions