Dell R610 Server User Manual


 
32 About Your System
E1A15 SAS cable B
failure.
Check
connection.
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
E2010 Memory not
detected.
Inspect
DIMMs.
No memory was detected in
the system.
Install memory or reseat
the memory modules. See
"System Memory" or
"Troubleshooting System
Memory."
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable. Error
detected during memory
configuration.
See "Troubleshooting
System Memory."
E2012 Memory
configured
but unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory."
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory."
E2014 CMOS RAM
failure.
Power cycle
AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Table 1-1. LCD Status Messages (continued)
Code Text Cause Corrective Actions