Dell R610 Server User Manual


 
38 About Your System
Alert! iDRAC6 not
responding.
Rebooting.
The iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization. The
system will reboot.
Wait for the system to
reboot.
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The iDRAC6 is not
responding.
The iDRAC6 was remotely
reset while system was
booting
After AC recovery, the
iDRAC6 takes longer than
normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a DIMM has
failed) so that node
interleaving cannot be
supported. The system will
run but node interleaving will
be disabled.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
see "System Memory." If the
problem persists, see
"Troubleshooting System
Memory."
Table 1-2. System Messages (continued)
Message Causes Corrective Actions