Dell R610 Server User Manual


 
Installing System Components 89
Removing the Power Supply Blank
If you are installing a second power supply, remove the power supply blank in
bay PS2 by pulling outward on the blank.
CAUTION: To ensure proper system cooling, the power supply blank must be
installed in power supply bay PS2 in a non-redundant configuration. Remove the
power supply blank only if you are installing a second power supply.
Installing the Power Supply Blank
NOTE: Install the power supply blank only in power supply bay PS2.
To install the power supply blank, align the blank with the power supply bay
and insert the blank into the chassis until it clicks into place.
Expansion Cards
Expansion Card Installation Guidelines
Your system supports one or two
x8 Gen2
PCIe expansion cards installed in
connectors on two expansion-card risers.
CAUTION: Expansion cards can only be installed in the slots on the two
expansion-card risers. Do not attempt to install expansion cards directly into the
riser connectors on the system board.
Both expansion slots support full-height, half-length cards.
The expansion-card slots are not hot-swappable.
PCI Express Generation 1 and Generation 2 expansion cards are supported
in both slots.
CAUTION: To ensure proper cooling, only one of the two expansion cards can
have a power consumption of greater than 15W (up to 25W maximum), not
including the integrated storage controller.
Table 3-1 provides a guide for installing expansion cards to ensure proper
cooling and mechanical fit. The expansion cards with the highest priority
should be installed first using the slot priority indicated. All other
expansion cards should be installed in card priority and slot priority order.