62
(1) Communications parameters setting screen
Selecting "1:PARAMETER" on the SET OPTICAL
screen calls up the screen shown at left.
Highlighted is the current setting.
Select the desired transmission speed by using
the numerical keys or
and keys, and then
press the ENT key.
To return to the SET OPTICAL screen, press the C
key.
(2) Communications protocol option screen
Selecting "2: PROTOCOL" on the SET OPTICAL
screen calls up the screen shown at left.
Highlighted is the current setting.
1 SERIAL No.: Selects whether or not the
system will add serial num-
bers to data blocks.
2 H. PARITY: Selects whether or not the
system will add a horizontal
parity.
3 LINKUP TIME: Selects the timeout length (in
seconds) to be applied when
a link is to be established.
4 FIELD SPACE: Selects whether space codes
in the tail of a data field will
be ignored or handled as data.
Select a desired item by using the numerical keys
or
and keys. Then select a desired setting
by using the
and keys.
To return to the SET OPTICAL screen, press the C
key.
If the BHT-Ir protocol has been selected, the
serial number and horizontal parity settings
will be ignored.
SET PARAMETER
< OPTICAL >
1:TRANSMIT SPEED:
2400 9600 19200
38400 57600 115200
SET PROTOCOL
< OPTICAL >
1:SERIAL No. : ON OFF
2:H.PARITY : ON OFF
3:LINKUP TIME:
None 30 60 90 120
4:FIELD SPACE:
Ignore Data