Dialogic 6.2 Fax Machine User Manual


 
boardmon
November 2009 128
the state of the signaling bits and alarms. It also counts the errors
(e.g., framing errors, CRC errors, clock slips, BPVs) on each span. It
only works with spans that are configured for robbed-bit signaling
and where telephony connections have been made.
The spans are numbered starting from 1 which is the first interface
on a module.
The btcall.cfg file is the user configuration file. The boardmon
application is found in the bapp.src directory.
Command Syntax
boardmon [-m <mod>] [-s <span>] [-d] [-v] [-h]
While the program is running you can press a key to reset the error
counters or to quit. When running under Unix, you must press
Enter after pressing the key.
Arguments
-m <mod> Use specified module (default 2)
-s <span> Use specified span only [1-4] (default all)
-d Enable program debug mode
-v Enable Bfv API debug mode
-h Help
1 Reset error counters for span 1
2 Reset error counters for span 2
3 Reset error counters for span 3
4 Reset error counters for span 4
r or R Reset error counters for all spans
q or Q Quit the program