Dialogic 6.2 Fax Machine User Manual


 
Making Hookflash Transfers
November 2009 181
To configure using configuration files:
Set the port configuration for T1 RBS using the callctrl.cfg
configuration file:
port_config=t1_robbed_bit
or for Analog, set:
port_config=analog
Set the protocol file for T1 Robbed Bit using the callctrl.cfg
configuration file:
protocol_file=C:\Brooktrout\Boston\config\winkstart.lec
and for Analog, the protocol file is:
protocol_file=C:\Brooktrout\Boston\config\analog_loopstart_us.lec
Set the transfer_variant using the callctrl.cfg configuration
file:
transfer_variant=hookflash
The flash duration is set:
flash_hook_duration=50
Set the country code using the btcall.cfg configuration file:
country_code 0010
Country codes are listed in:
C:\Brooktrout\Boston\bfv.api\inc\ccode.h
Hookflash transfer is the only analog explicit call transfer method.
Using BSMI Applications
In T1 and analog BSMI applications, use L4L3mTX_HOOKFLASH
to set the duration of the hookflash signal. The field to set the signal
is:
L4_to_L3_struct.data.signal_duration_data = 0;
The duration of the hookflash signal is in milliseconds. The default
value is 0, which is equal to 500ms in duration. The maximum
setting is 64k.
For more information on the
Brooktrout Configuration Tool, refer to the
chapter on using the configuration tool in the installation and
configuration guide that came with your software.