MIB Description
5.1 Overview
You can use the CGM-CONTROL-MIB to access and control the clock generator module PMC-
CGM that is used in your AdvancedTCA system.
It is located at
.iso.org.dod.internet.private.enterprises.forceComputers.cgmControlMIB.motCgm (OID:
.1.3.6.1.4.1
.3656.8152.1).
The CGM-CONTROL-MIB contains the following three main branches.
5.2 cgmControl
The cgmControl branch contains the following information:
z cgmInputTable - for details refer to Table 5-2 on page 47.
For details on how to use these MIB objects refer to Configure the Reference Clock on page
41.
z cgmBitsTable - for details refer to Table 5-4 on page 49.
For details on how to use these MIB objects refer to Configure the BITS Interface on page
39.
z Various MIB objects that are described in Table 5-5 on page 53.
For details on how to use these MIB objects refer to Configure the Interface Mode on page
39, Configure Initial Master/Slave Role on page 40.
The cgmInputTable (OID: .1.3.6.1.4.1
.3656.8152.1.1.1) uses the instance number as defined
in Table "Input Assignments" on page 48 as index.
Table 5-1 MIB Structure
Branch Used for...
cgmControl Controlling and configuring the BITS interfaces and the PLL
cgmSys Maintianing the PMC-CGM (FW/SW upgrade, event log)
cgmClkDist Distributing clocks in the chassis
Table 5-2 cgmInputTable
OID MIB Object Description Access
.1.1.1.1.2 cgmInputName Named source for this input. If the string is
empty the input is not connected.
r