Emerson PMC-CGM Computer Hardware User Manual


 
cgmSys MIB Description
PMC-CGM Installation and Use (6806800D53C)
55
5.3 cgmSys
The cgmSys branch contains the following information:
z cgmEventTable - for details refer to Table 5-6 on page 55.
z Various MIB objects that are described in Table 5-8 on page 58.
For a description on how to use these objects refer to Configure Parameters for Event
Handling on page 44, Perform Firmware/Software Upgrade on page 42.
The cgmEventTable (OID:.1.3.6.1.4.1
.3656.8152.1.3.1) uses cgmEventNumber as index. The
elements of the trap definiton cgmLogEvent (OID:.1.3.6.1.4.1.3656.8152.1.2.0.1) is identical to
the elements defined in cgmEventTable.
.1.1.41 cgmCLK2OutputFrequency The output frequency of CLK2:
0 - CLK2 output disabled
1 - 19.44 MHz
Default value is (1).
r/w
.1.1.42 cgmCLK3OutputFrequency Not supported on PMC-CGM r/w
.1.1.43 cgmCLK1OutputFramePulse The output frame pulse of the T1 clock:
0 - Not inverted, not pulsed
1 - Not inverted, pulsed
2 - Inverted, not pulsed
3 - Inverted, pulsed
Default value is (0).
r/w
.1.1.44 cgmT4ClkSquelch When set to 0 (enable) the output of the T4 PLL
is squelched if no valid input is selected.
If set to 1 (disable) an output is provided in any
case.
Table 5-5 cgmControl Elements (continued)
OID MIB Object Description Access
Table 5-6 cgmEventTable
OID MIB Object Description Access
.1.3.1.1.2 cgmEventTime System time stamp when event occurred (this is the
module's run-time since power-up).
r
.1.3.1.1.3 cgmEventSeverity The event's severity level
1. Critical (0): An error has occurred which needs
immediate attention.
2. Warnings (1): An error has occurred which may affect
board operation but does not require immediate attention.
3. Events (2): An event occurred in a board subsystem
which may need attention (e.g. the PLL gained lock).
4. Information (3): Various information messages helpful
for troubleshooting or monitoring the state of the CGM
module.
r