PMC-CGM Installation and Use (6806800D53C)
MIB Description cgmControl
50
.1.1.2.1.6 dsx1LoopbackConfig Loopback mode
Loopback mode disabled (1)
local (payload) loopback - Tx to Rx (2)
line loopback - Rx to Tx (3)
Default value is disabled (1).
r/w
.1.1.2.1.7 dsx1LineStatus Current line status. This is a bit mask encoding the
following states:
-Bit 0 (value 0x01): Yellow alarm condition
-Bit 3 (value 0x08): Alarm condition
-Bit 5 (value 0x20): Loss of Frame condition
-Bit 6 (value 0x40): Loss of Signal condition
r
.1.1.2.1.10 bitsCurSsm The last received synchronization status message
Not yet supported
r
.1.1.2.1.11 bitsSsmE1SaSelect Selects on which Sa bit the E1 synchronization
status message is expected.
Default value is (4).
Not yet supported
r/w
.1.1.2.1.13 bitsLiuJaEn Enable jitter attenuator
Default value is disabled (0).
r/w
.1.1.2.1.14 bitsLiuJaDs Jitter attenuator depth (32 or 128 bits)
Default value is 128 bits (0).
r/w
.1.1.2.1.16 bitsLiuEgl Receive equalizer gain limit for T1 (-36/-15dB) and
E1 (-43/-12dB)
Default value is (0).
r/w
.1.1.2.1.18 bitsLiuE1Lbo E1 line build-out select in Ohm (without and with
high return loss)
120 Ohm (1)
120 Ohm with high return loss (3)
Default value is (1).
r/w
.1.1.2.1.19 bitsLiuT1Lbo T1 line build-out select for DSX-1 application in
feet.
0 to 133 ft (0)
133 to 266 (1)
266 to 399 (2)
399 to 533 (3)
533 to 655 (4)
Default value is (0).
r/w
Table 5-4 cgmBitsTable (continued)
OID MIB Object Description Access