Emerson P/N MMI-20019808 Network Card User Manual


 
Device Profile
User Manual 31
Reset service
When the Identity Object receives a Reset request, it:
Determines if it can provide the type of reset requested
Responds to the request
Attempts to perform the type of reset requested
B.2.2 Message Router, Class 02h
The Message Router Object provides a messaging connection point through which a Client may
address a service to any object class or instance residing in the physical device.
B.2.3 Assembly Object, Class 04h
The Assembly Object binds attributes of multiple objects, which allows data to or from each
object to be sent or received over a single connection. Assembly objects can be used to bind
input data or output data. The terms “input” and “output” are defined from the network's point
of view. An input produces data on the network and an output consumes data from the
network.
This object provides access to the I/O Data in the Input and Output Data areas in the
Micro Motion EtherNet/IP Module.
4... 7 Extended Device Status:
Value Meaning
0000b Unknown
0010b Faulted I/O Connection
0011b No I/O connection established
0100b Non-volatile configuration bad
0110b Connection in Run mode
0111b Connection in Idle mode
(other) (reserved)
8 Set for minor recoverable faults
9Set for minor unrecoverable faults
10 Set for major recoverable faults
11 Set for major unrecoverable faults
12... 15 (reserved)