Emerson P/N MMI-20019808 Network Card User Manual


 
Device Profile
User Manual 47
B.3.9 Input assembly for petroleum measurement configuration
Byte Access Name Type Notes
0–3 Get Mass flow rate Float
4–7 Get Density Float
8–11 Get Temperature Float
12–15 Get Volume flow rate (liquid
volume)
Float
16–19 Get Mass total Float
20–23 Get Volume total Float
24–27 Get Drive gain Float
28–29 Get Status word U16 or Word For Model 1700 Analog, Model 2700
Analog, Model 1500 Analog, Model
2500, and all Series 3000 transmitters:
SNS Status Word 1 (see Section B.7.1)
For MVD Direct Connect and 9739 MVD
transmitters: SNS Status Word 2 (see
Section B.7.2)
30-31 Get Status word U16 or Word For Model 1700 Analog, Model 2700
Analog, Model 1500 Analog, Model
2500, and all Series 3000 transmitters:
SNS Status Word 2 (see Section B.7.2)
For MVD Direct Connect and 9739 MVD
transmitters: SNS Status Word 1 (see
Section B.7.1)
32–35 Get Temperature-corrected
density
Float
36–39 Get CTL Float
40–43 Get Temperature-corrected
volume flow
Float
44–47 Get Temperature-corrected
volume total
Float
48–51 Get Temperature-corrected
volume inventory
Float
52–55 Get Average temperature-
corrected density
Float
56–59 Get Average temperature Float