Extron electronic 12800 Switch User Manual


 
Prograing Guide, cont’d
Matrix 12800 Switchers • Programming Guide
4-10
PRELIMINARY
Coand ASCII coand
(hot to witcher)
Response
(witcher to hot)
Additional
decription
Create and recall preet
N
•Ifyoutrytorecallapresetthatisnotsaved,thematrixswitcherrespondswiththeerrorcodeE11.
If you try to save a preset for a room that has not been created, the matrix switcher responds with the error code E21.
Outputs must be assigned to a room before a room preset can be created.
The following characters are invalid or not recommended in preset names: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
Save current the current
configuration as a global
preset
X(
, Spr
X(]
Command character is a
comma.
Example:
9,
Spr09
]
Save current ties as preset 9.
Direct write process
N
The direct write of a global preset should always be preceded by a clear global preset ties command of that same
preset number, as shown below. In a directly-written preset, the input tied to each output position (or no tied input)
remains unchanged unless overwritten or cleared.
If you do not clear the ties in a global preset number before you directly write a global preset to that number, ties that
are part of the previous version of the specified preset with the same number can unexpectedly become part of the newly-
created preset.
Clear a global preset ties
E
+
X1)
P0*!
}
Spr
X1)]
Clear all ties in preset
X1)
.
Directly write a global
preset
E
+
X(
P
X!
*
X@
!...
X!
*
X@
$ Spr
X(]
You can enter as many
ties as are valid for your
virtualization. Tie all (!), tie
RGBHV (&), tie video (%),
and tie audio ($) commands
are all valid.
Example:
E
+27P0*!
}
Spr27
]
Clear all ties in preset 27.
+27P22*5!15*29$13*26%3*8&
Esc
Brackets are shown to separate
ties for clarity only. Create
global preset 27, which ties
video and audio input 22 to
output 5, RGBHV input 15 to
output 29, video input 13 to
output 26, and audio input 3
to output 8.
Spr27
]
Recall a global preset
X(
. Rpr
X(]
Command character is a
period.
Example:
5.
Rpr05
]
Recall preset 5, which
becomes the current
configuration.
Write room outputs
EX1)
,
X@
1
,
X@
2
, ...
X@
n
MR
}
See notes.
Mpr
X1)
,
X@
1
,
X@
2
, ...
X@
n
]
N
•Outputsmustbeassignedtoaroombeforearoompresetcanbecreated.
A room can contain a maximum of 16 outputs.
An output can belong to only one room.
The maximum number of rooms (
X1)
s) is 32.
If no room name is assigned, the default name is “Room #
X1)
X@
1
,•
X@
2
,•
X@
3
”.
Example:
E
8,3,04,5,6MR
}
Mpr8,003,004,005,006
]
Outputs 3, 4, 5, and 6 are
assigned to room 8.
Coand and repone table for SIS coand (continued)
N
X(
= Preset number 01 – 64
X!
= Input number 000 – maximum number of inputs (000 = untied)
X@
= Output number 001 – maximum number of outputs
X1)
= Room number 00 – 32