Ethernet Data Port
Set current connection port
timeout
E 0 * X12( TC } Pti0 * X12( ]
Set number of seconds (in tens
of seconds) before timeout on IP
connections.
X12( = 1 through 65000.
View current connection port
timeout
E 0 TC } X12( ]
Set global port timeout
E 1* X12( TC } Pti1* X12( ]
View global port timeout
E 1TC } X12( ]
IP Setup Commands
Set unit name
E X8@ CN } IpnX8@ ] Set DVS unit name X8@. X8@
can be up to 24 characters
consisting of A to Z, a to z,
0 through 9, and hyphen (-).
The first letter must be
alphabetical; the last one must
not be a hyphen.
View unit name
E CN } X8@ ]
Reset unit name to factory
default
24
ECN } IpnX11% ]
Reset DVS name to its factory
default name X11%.
X11% consists of the model name
and the last three pairs of the
MAC address.
Example:
ECN } IpnDVS-510-SA-05-62-3D ]
Set time and date
24
E X8# CT } Ipt X8# ] X8# is the local date and time
format. The set format is
MM/DD/YY-HH:MM:SS. (The
hours, minutes, and seconds can
also be separated by periods.)
Examples:
11/13/06-10:54:00 or
11/13/06-10.54.00
View time and date
E CT } X8# ]
Set GMT offset
24
E X7# CZ } Ipz X7# ]
Set the Greenwich Mean Time
(GMT) offset value (X7#) for
the DVS location. GMT offset
(-12.00 to +14.00) represents
the time difference in hours
and minutes (± hh:mm relative
to Greenwich, England). The
plus sign and leading zero are
optional.
X7# is in the format hh:mm.
Example:
5:30 or 5.30 = +05:30
NOTE: In the command, the divider between hours and minutes can be a colon or a period. In the response, it is a colon.
Example:
E 8.0CZ } Ipz+08:00 ]
View GMT offset
E CZ } X7# ]