Extron electronic IPI 100 Switch User Manual


 
SIS Programming and Contro, cont’d
IPI 100 and IPI 200 Series • SIS Programming and Control
B-6
X1#
= Local date and time format
Setformat(MM/DD/YY‑HH:MM:SS).
Example: 01/18/05-10:54:00.
Readformat(dayofweek,datemonthyearHH:MM:SS).
Example: Tue, 18 Jan 2005 18:19:33.
X1$
= IP address or subnet mask (xxx.xxx.xxx.xxx). Leading zeros in each of four
fields are optional in setting values, and they are suppressed in returned
values.
IPI’sdefaultaddress:192.168.254.254
Default broadcast address: 255.255.255.255.
X1*
=Hardware(MAC)address(xx‑xx‑xx‑xx‑xx‑xx)(00‑05‑A6‑xx‑xx‑xx)
X2@
=Verbose/responsemodestatus:
0=clear/none,defaultforTelnetconnections;responsesarenotechoedto
the host
1=verbosemodeison,defaultforRS‑232hostcontrol;responsesareechoed
to the host and displayed to the user
2 = send tagged responses for queries
3 = verbose mode is on and tagged responses are sent for queries
N
If tagged responses are enabled, all read commands return the constant string +
data, the same as for setting a value. For example, for
E
CN
}
, the response
is Ipn•
X1@ ]
rather than just the data.
X3#
= Password(minimumlength=4characters,maximumlength=12characters,
no special characters are allowed)
N
A user password cannot be assigned if no administrator password exists; the E14
error code will be returned. If the administrator password is cleared, then the
user password is also removed.
X3$
= Daylight saving time
0 =DaylightSavingTimeoff/ignore
1=DaylightSavingTimeon(USA/Canada)
2 =DaylightSavingTimeon(Europe)
3 =DaylightSavingTimeon(Brazil)
X4!
= Passwordtodisplayonscreen(responsetopasswordqueryorset).When
theMLCconnectstoahostdeviceviaRS‑232,thepassword(
X3#
), itself, is the
response.WhentheconnectionisviaIP,
X4!
is4asterisks(****)ifapassword
hasbeenassigned,oritisanemptyeld()ifapasswordhasn’tbeen
assigned.
X4(
= Defaultname:acombinationofthemodelnameandthelast3pairsofthe
IPI200series’MACaddress
X5@
= Connection’ssecuritylevel
11 = user
12 = administrator
X6#
= Pulsetimein20mspercount.Ifthisparameterismissingor=0,thenpulse
length=default=25=500ms.1=20ms(minimumpulsetime)to65535=
1310700ms(maximumpulsetime).