Extron electronic IPI 100 Switch User Manual


 
SIS Programming and Contro, cont’d
IPI 100 and IPI 200 Series • SIS Programming and Control
B-8
Command/response tabe for SIS commands
Command ASCII (Tenet
(host to intercom
URL Encoded
(host to intercom
Response
(intercom to host
Additiona Description
Reay functions
Force relay on 1*1O 1%2A1O
Rly1*1
]
Turn relay on.
Force relay off 1*0O
1%2A0O
Rly1*0
]
Turn relay off.
Toggle relay 1*2O 1%2A2O
Rly1*
X%]
Togglerelayon/off.
X%
=1(on)or0(off).
Pulse relay
1*3*
X6#
O 1%2A3%2A
X6#
O Rly1*
X%]
Rly1*
X%]
Setrelay’spulsetime(
X6#
) in
20msincrementsfrom1(20ms,
minimum)to65535(1310700ms,
maximum).
Defaultpulselengthis25=500ms.
N
If the verbose mode is enabled, there are two responses from the unit because the relay is pulsed. During a pulse, the relay is
toggled to its opposite state and then back to the original state.
Viewtherelay
state
1O 1O
Rly1*
X%]
Front pane security ockout modes (executive modes
Off
24
0X 0X
Exe0
]
Executive mode is off.
On
24
1X 1X
Exe 1
]
Executive mode is on.
Viewlockout
mode status
X X
X20(] X20(
= Front panel lockout
(executive mode) status
0=off/unlocked(default)
1=on,disable/lockthefrontpanel
Example:
X X
0
]
Executive mode is off.
Status commands
Viewall
voltage and
temperature
status
11S 11S shows responses to commands
12S•13S•14S•15S•16S•20S
]
View+12V
P/Svoltage
12S 12S
+
X20^]
X20^
=Voltage(involts)
View+5VIR
receiver port
voltage
13S 13S
+
X20^]
View+3.3V
IPLink/FPGA
voltage
14S 14S
+
X20^]
View+1.5V
FPGA voltage
15S 15S
+
X20^]
Viewinternal
temp. status
20S 20S
X20&] X20&
=Temperature in degrees
Celsius(theresponseis3digits
including leading zeros)