Extron electronic MMX 32 VGA MTP Switch User Manual


 
MMX 32 VGA MTP • Installation and Operation 9
TP Cable Termination
NOTE: RJ-45 termination must comply with the TIA/EIA T 568A or TIA/EIA T 568B wiring
standards for all connections. If you are using Skew-Free™ A/V UTP cable, then
you should use the TIA/EIA T 568A standard only.
Figure 9 details the recommended termination of TP cables with RJ-45 connectors in
accordance with the TIA/EIA T 568A or TIA/EIA T 568B wiring standards. You can use either
standard with CAT 5 cable, but ensure that you use the same standard on both ends of the
cable.
Clip Down
1
1&2
3&6 4&5
7&8
2 3 4 5 6 7 8
1 Pins 2 3 4 5 6 7 8
RJ-45
connector
Twisted
Pairs
Figure 9. TP Cable Termination
NOTES: Skew-Free A/V cable is not recommended for Ethernet/LAN applications.
Skew-Free cable is specially designed for compatibility with Extron Twisted Pair
products, wired using the TIA/EIA 568 A standard.
The green, brown, and blue pairs of this cable have virtually identical lengths
and should be used to transmit the RGB signals.
The orange pair of this cable has a different length and should not be used to
transmit the RGB signals.
Pin
568 A
Wire color
568 B
Wire color Signal
1 White-green White-orange Red+/V. sync+
2 Green Orange Red-/V. sync-
3 White-orange White-green Mono audio+
4 Blue Blue Green+
5 White-blue White-blue Green-
6 Orange Green Mono audio-
7 White-brown White-brown Blue+/H. sync+
8 Brown Brown Blue-/H. sync-
NOTE: If you use Skew-Free™ A/V cable, use the TIA/EIA T