Extron electronic MMX 32 VGA MTP Switch User Manual


 
MMX 32 VGA MTP • Remote Control 21
8. Click Browse in the New Firmware File field. Locate the update file you downloaded
from the Web site and click Open.
NOTE: The firmware update file must have an .s19 extension. If it does not have
that extension, it could cause the unit to stop functioning.
9. Click Add. The Firmware Loader window will appear.
10. Click Begin on the upper right hand corner of the Firmware Loader window. The
program will begin to load the update.
11. When the program is finished loading the update, click Exit. The Universal Switcher
Control Program closes.
NOTE: If the firmware loader utility exits before the status bar has progressed
completely across the indicator window, the firmware may be corrupted
and may no longer respond to the Universal Switcher Control Program or
the Firmware Loader utility. In this condition, the firmware upload can be
accomplished only by using SIS commands. See “Loading Firmware Using
an SIS Command” on page 16.
Using the help system
For information about program features, you can access the help program in any of the
following ways:
From the Extron program group, double-click the Universal Switcher Help icon.
From within the Universal Switcher Control Program, click Help on the task bar.
From within the Universal Switcher Control Program, press the F1 key.
Contact Closure Control
The MMX 32 VGA MTP can be controlled remotely using the optional Extron MMX 32 AAP
contact closure control panel (part number 70-277-01, -11, or -21) or the MMX 32 MAAP
contact closure panel (part number 70-277-12 or -22). Each panel controls one output and
has three input selector buttons and LEDs.
The contact closure system uses the two 5-pole captive screw connectors, which control
outputs 1 and 2 separately. Each contact closure pin corresponds to an input/output
connection, or tie. A tie is made when one pin is momentarily connected to ground. Each
pin returns a signal to the remote control panel after a tie is made, lighting the control panel
LED corresponding to the selected input. A +5 V port is used when controlling the output
with an MMX 32 AAP/MAAP panel.