Fluke DSP-2000 Network Card User Manual


 
DSP-100/2000
Users Manual
8-12
Impulse Noise
Adjustable from 100 mV to 500 mV in 10 mV steps. The default threshold is
270 mV.
Monitors either polarity of noise on pair 3, 6.
Minimum detectable impulse width: 10 ns
Model DSP-100 LAN Traffic
Monitors 10 Mb/s Ethernet only; UTP or coaxial cable.
Monitors pair 3, 6 for either polarity of data.
Generates a positive polarity link pulse on pair 1, 2.
Model DSP-2000 LAN Traffic
Monitors 10BaseT traffic using the MONITOR RJ45 jack. Monitors pair 3, 6 for
either polarity of traffic. Generates a positive polarity link pulse on pair 1,2.
Monitors 100BaseTX traffic Ethernet traffic using the MONITOR RJ45 jack.
Monitors pair 3, 6 for either polarity of traffic. Generates 100BaseTX link signals
on pair 1, 2.
Auto-negotiates between 10BaseT and 100BaseTX using the MONITOR RJ45
jack. Monitors pair 3, 6 for 10BaseT or 100BaseTX link pulses. Generates Auto-
Negotiation signals on pair 1, 2.
Monitors 10 Mb/s Ethernet traffic using the COAX jack with the RJ45 to BNC
adapter provided.
Serial Interface
Connector: DB9 (DTE male)
Baud rate: 1200 to 38,400 baud
Flow control: hardware, XON/XOFF, or none
Data format: 8 data bits, 1 stop bit, no parity
Printer formats: Epson, HP LaserJet, or Text Only