Fluke DSP-2000 Network Card User Manual


 
Running Individual Tests
The TDX Analyzer
4
4-7
If the test tool does not detect a remote, the following message appears:
NO REMOTE DETECTED. To run the TDX analyzer, press E. To
restart the analyzer and scan for the remote again, press T. To return to the first
Single Test screen, press e.
TDX Analyzer Results
When the TDX analyzer test is complete, the TDX analyzer results screen
appears. Table 4-2 describes the items on the analyzer screen.
Table 4-2. Items on the TDX Analyzer Results Screen
Item Description
Pairs
The cable pairs relevant to the results.
Peak
The highest magnitude of crosstalk measured on the cable pair. A peak over
50 indicates a crosstalk level that exceeds the limit specified by the selected
test standard. Crosstalk levels are adjusted to compensate for cable
attenuation.
Distance
The measured distance from the main unit to the peak crosstalk value.
#
View Plot
Press to see a plot that shows where crosstalk is detected on the cable.