Freedom9 IP 800 Switch User Manual


 
freeView IP 800 User’s Manual
32
CONSOLE ON/OFF, etc.
“OSD: 10 SEC” is the amount of time the system name will be displayed on the monitor after
the computer is selected. This value can be set from 05 sec to 99 sec. The factory default
value is 10 sec.
“SCAN TIME” is the scan interval from one PC port to next PC during Auto Scan mode. The
default scan time is 10 sec and the maximum scan time is 99 sec.
“CHANGE PASSWORD” is used to change the password for accessing the systems. The
default password is 8 digits “00000000“.
An enter password window appears when you select this item. The maximum password is 8
digits. After you key in the password and press the <Enter> key, another window appears to
confirm the password you entered.
You need to retype the password again to verify.
“CONSOLE ON/OFF“ determines whether the password needs to be entered to access the
console. “CONSOLE ON” means that any user can access the console. “CONSOLE OFF”
means that the password needs to be entered to access the console. Once the password is