Fujitsu BX600 S3 Server User Manual


 
BX600 S3 Operating Manual 145
14 Troubleshooting and Tips
V CAUTION!
Please note the safety instructions in the chapter “Important Notes” on
page 21.
If a fault occurs, try to correct it as described
in this chapter
in the chapters for the components installed
in the documentation for the connected devices
in the help system of the individual programs
If you do not manage to correct the problem, proceed as follows:
Ê Make a note of the steps and the circumstances that led to the fault. Also
make a note of any error messages displayed.
Ê Switch OFF the defective server blade or the system.
Ê Contact your customer service.
14.1 System Power LED Remains Unlit
The power LED (see figure 14 on page 50) remains unlit after you have
switched ON your system:
Wrongly connected power cables
Ê Make sure that the power cables are correctly connected to the system
power supply units and to the mains socket strip of the rack (see section
“Connecting the System to the Mains” on page 46).
Power supply overloaded
Ê Unplug the power cables from the insulated sockets of the power supply
units.
Ê Wait a few seconds and plug the power plugs into the insulated sockets
again.
Ê Switch ON your system.