Fujitsu BX600 S3 Server User Manual


 
66 Operating Manual BX600 S3
Updating BX600 System Components Preparation for Use and Operation
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: H:\April\PRIMERGY_Rebranding\von Walter\bx600_s3_ba\BX600S3_en\blade-us.k05
Ê Extract the firmware file to the root directory of the TFTP file system. For
information on the image file names, see the readme file of the update
package.
Ê Start an Internet browser on the client server. Enter the IP address specified
above in the address field. Enter the user name and password admin. The
home page is displayed.
Ê In the navigation bar choose Flash/File.
I Only two operation code image files can be stored on the switch blade. If
there are already two image files stored, you must remove at least one of
them before updating the firmware. It is recommended that you remove
the older file (i.e. the file with the lower number).
Ê Expand the File Name list (red arrow) in the Remove Operation Code Image File
section to check if there are already two image files stored on the switch
blade. If so, select the older one in the File Name list and click Remove File.
Figure 24: Removing an operation code image file
Ê Enter TFTP Server IP Address, Source File Name and Destination File Name.