40 Operating Manual BX600 S3
Installing the System in the Rack Installing the Hardware
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: H:\April\PRIMERGY_Rebranding\von Walter\bx600_s3_ba\BX600S3_en\blade-us.k04
4.3.2 Mounting/Removing the Basic Unit
V CAUTION!
For safety reasons, at least two people are required to mount or
remove the PRIMERGY BX600 S3 basic unit because of its weight
and size.
Please note the relevant safety instructions in section “Notes on Installing
in the Rack” on page 27.
Before lifting the basic unit into the rack, remove server blades, fan units
and power supplies from the basic unit to reduce weight.
Figure 8: Mounting the basic unit
Ê Note the slot assignment of the server blades so that you can insert them
correctly again once you have lifted the basic unit into the rack.
Ê Remove server blades, fan units and power supplies from the system unit to
reduce weight (for assembly instructions see section “Adding a Server Blade
to the Basic Unit” on page 74, section “Replacing a Power Supply Unit” on
page 133 and section “Replacing the Fan Unit” on page 141).
Ê Lift the basic unit onto the two carrier rails.
Ê Slide the basic unit into the rack (1).
Ê Secure the basic unit in the rack using the four knurled screws (2).