BX600 S3 Operating Manual 59
Preparation for Use and Operation Management Blade Configuration
I The management blade LAN controller only runs at 10 Mbit/sec.
Duplex mode must be defined manually via the Agent NIC Duplex Mode
(see figure 20 below).
Figure 20: Agent NIC Duplex Mode menu
Ê Enter 2 if the preset duplex mode value needs to be altered or 0.
I The transfer rate of 10 Mbit/sec and the duplex mode of the manage-
ment blade must comply with the client LAN controller! Automatic
synchronization is not supported by the management blade LAN con-
troller.
Ê Enter 0 in this menu and in the preceding menus to leave the management
blade console menu.
Ê Close the HyperTerminal session.
Ê Unplug the power cable from the basic unit and plug it in again to reboot the
management blade.
I This ensures that the management blade continues to act as the
master after the restart. A restart without interruption to the power
supply would cause the master/slave assignment to change.
The management blade can now be accessed via the LAN. For more informa-
tion on the management blade configuration, see the manual “PRIMERGY BX
Blade Server Systems: RemoteView Management Blade - User Interface
Description”. Information on the configuration of the various switch blade
models can be found in sparate manuals, see “Related Publications” on
page 157.