Fujitsu M3099GH Scanner User Manual


 
7-14
<Screen 37>
When you set the picking time, you must set as follows:
<Screen 36>
<Screen 38>
<Screen 39>
H
E
T
ER
C
ONA
T
ROL
ON
When you set the heater control, you must set as follows:
Setting heater control
1 In Screen 2, press
Mode 1
17 times (18 times
for M3099GX/GH) to go to the HEATER
CONTROL screen. <Screen 38>
2 Press
Mode 2
to display Screen 39. If “ON”
is displayed, the heater control will be done.
If “OFF” is displayed, warming-up will finish
within 30 seconds, if necessary. When the
heater is broken, please set “OFF”. Each
time
Mode 1
is pressed, “ON” and “OFF”
appear alternately. The setting is stored in
EEPROM automatically.
3 Press
Mode 2
to display Screen 38. When
you close the setup mode, press
Stop
.
(Blinking)
Setting hopper time
1 In Screen 2, press
Mode 1
16 times (17 times
for M3099GX/GH) to display HOPPER
TIMER screen. <Screen 36>
2 Press
Mode 2
to display Screen 37.
(The default setting is 7 seconds.)
3 In Screen 37, press
Mode 1
until the digit you
want to change blinks. Then press
Mode 2
until the value you want to select appears.
(The selectable range is from 0 to 30 seconds
in steps of 1 second.)
4 Press
Mode 1
and
Mode 2
at the same time to
display Screen 36. The settings are stored in
EEPROM.
5 When you close the setup mode, press
Stop
.
<
>
<
>
SE
T
U P M O D
E
T
I
ME R
H
OPPER
S
XX
T
I
ME R
H
OPPER
<
>
<
>
SE
T
U P M O D
E
H
E
T
ER
C
ONA
T
ROL
15-Chap. (7) 98.2.20, 10:59 AM14