Graco 312776F Webcam User Manual


 
Run Mode Screens
22 312776F
Status Screen
•Use the Up or Down keys to scroll through the
Run screens.
Press the Setup key to enter the Setup screens
from the Status screen.
The other keys have no function in this Status
screen.
Key to F
IG. 10:
Active Recipe: shows the active recipe.
NOTE: At power up the system defaults to Recipe
61, which is not a valid recipe number.
Target Ratio: for the active recipe. The ratio can be
from 0.0:1–50.0:1, in 0.1 increments.
Actual Ratio: in hundredths, calculated after each
dose of A and B.
Potlife Timer: shows remaining potlife time in min-
utes. Two times are shown if there are two guns.
Status Bar: shows current alarm or operation mode
(standby, mix, purge, recipe change, or the current
alarm).
Current Flow Rate: in cc/min.
Animation: when the gun is triggered, the gun
appears to spray and the component A or B hose
lights up, showing which component dose valve is
open.
Current Date and Time
Screen Number and Scroll Arrows: displays the
current screen number and the total number of
screens in a group. The Up and Down arrows on the
right edge of the screen indicate the scroll feature.
The total number of screens in some groups may
vary depending on system configuration selections.
Lock Symbol: indicates that Setup screens are
password protected. See page 26.
F
IG. 10. Status Screen