Graco 312776F Webcam User Manual


 
Setup Mode
312776F 41
Recipe Setup Screen 5
This screen appears only if K-factor Input is set to “Rec-
ipe” in Option Screen 1, page 32.
K-factor A Meter
Enter the k-factor (cc/pulse) for flow meter A. This is the
amount of material that passes through the flow meter
per pulse (electrical pulse signal).
K-factor B Meter
Enter the k-factor (cc/pulse) for flow meter B.
K-factor Solvent Meter
This field only appears if Solvent Monitor in Configure
Screen 5, page 31, is set to “Meter.” Enter the k-factor
(cc/pulse) for the solvent flow meter.
Recipe Setup Screen 6
This screen appears only if Flow Rate Monitor is set to
“On” in Option Screen 2 on page 33.
Flow Rate Monitor
Select the desired flow rate monitoring (Off, Warning, or
Alarm).
Low Flow Limit
Enter the low flow rate limit (1 to 3999 cc/min).
High Flow Limit
Enter the high flow rate limit (1 to 3999 cc/min).
F
IG. 43. Recipe Setup Screen 5
FIG. 44. Recipe Setup Screen 6