Graco 312776F Webcam User Manual


 
Alarms and Warnings
80 312776F
Alarms and Warnings
NOTE: Do not use the fluid in the line that was dis-
pensed off ratio as it may not cure properly.
System Alarms
System alarms alert you of a problem and help prevent
off-ratio spraying. If an alarm occurs, operation stops
and the following occurs:
A red LED illuminates steadily or blinks on the
Booth Control.
Booth Control displays an alarm E-Code, E-1 to
E-28. See F
IG. 81.
Buzzer sounds (for E-2 only; see page 29 to set for
all alarms).
Status bar on the EasyKey Display shows the alarm
E-Code with a description (see Table 10).
System Warnings
Table 10 lists the System Warning Codes. Warnings do
not stop operation or sound an alarm. They are saved in
the date/time stamped log, which can be viewed on a
PC, using the ProMix 2KS Web Interface (see manual
313386).
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the
E-Code before resetting it. See Table 10. If you forget
which E-Code occurred, use the Alarms Screens (page
24) to view the last 10 alarms, with date and time
stamps.
To reset alarms, see Table 11. Many alarms can be
cleared by simply pressing the Alarm Reset
key.
F
IG. 81. Booth Control
TI11614A
Display
Recipe Indicator (green)
Alarm Indicator (red)
Table 10: System Alarm/Warning Codes
Code Description Details
E-1 Communication Error Alarm Page 81
E-2 Potlife Alarm Page 81
E-3 Ratio High Alarm Page 82
E-4 Ratio Low Alarm Page 83
E-5 Overdose A/B Dose Too Short Alarm Page 84
E-6 Overdose B/A Dose Too Short Alarm Page 84
E-7 Dose Time A Alarm Page 85
E-8 Dose Time B Alarm Page 85
E-9 Not used NA
E-10 Remote Stop Alarm Page 86
E-11 Purge Volume Alarm Page 86
E-12 CAN Network Communication Error
Alarm
Page 87
E-13 High Flow Alarm Page 88
E-14 Low Flow Alarm Page 88
E-15 System Idle Warning Page 88
E-16 Setup Change Warning Page 88
E-17 Power On Warning Page 88
E-18 Defaults Loaded Warning Page 88
E-19 I/O Alarm Page 89
E-20 Purge Initiate Alarm Page 90
E-21 Material Fill Alarm Page 90
E-22 Tank A Low Alarm Page 90
E-23 Tank B Low Alarm Page 90
E-24 Tank S Low Alarm Page 90
E-25 Auto Dump Complete Alarm Page 91
E-26 Color/Catalyst Purge Alarm Page 91
E-27 Color/Catalyst Fill Alarm Page 91
E-28 Mix Fill Push Complete Page 91