Alarm Troubleshooting
88 312776F
E-13: HIGH FLOW ALARM or E-14: LOW FLOW ALARM (may also be set as Warnings)
Cause Solution
Fluid system is producing too much or too little flow. Troubleshoot fluid system for restrictions, leaks,
exhausted fluid supply, incorrect settings, etc. Increase
or decrease flow rate, as required.
E-15: SYSTEM IDLE WARNING
Cause Solution
Mix input is high, but the gun has not been triggered for 2
minutes.
If not painting, clear alarm and resume operation.
If painting, shut down and inspect fluid meter and air flow
switch.
E-16: SETUP CHANGE WARNING
Cause Solution
The system setup parameters have been changed. No action required. See Event Log available through
advanced web interface.
E-17: POWER ON/POWER OFF WARNING
Cause Solution
The power to the system has been cycled. No action required. See Event Log available through
advanced web interface.
Voltage becoming too low due to weak power supply. Replace power supply. See Repair-Parts manual.
Power wires are disconnected or making intermittent
contact.
Check that all wires are securely connected. Ensure that
wires are not stretched too tightly.
Reset button has been pushed (S1 on EasyKey display
board, S3 on Autokey).
No action required. See Event Log available through
advanced web interface.
Software update is initiated on EasyKey. No action required. See Event Log available through
advanced web interface.
E-18: DEFAULTS LOADED WARNING
Cause Solution
The factory defaults have been installed on the system. No action required. See Event Log available through
advanced web interface.
Table 11. Alarm Troubleshooting