Graco 312776F Webcam User Manual


 
Setup Mode
36 312776F
Advanced Setup Screen 3
This screen appears only if Flush and Fill Input is set to
“Global” in Option Screen 1, page 32.
If Number of Guns is set to “2” in Configure Screen 4,
page 30, a Gun 2 column will appear in this screen.
First Purge Time
Enter the first purge time (0 to 999 seconds).
Total Chop Time
Enter the total chop time (0 to 999 seconds).
Final Purge Time
Enter the final purge time (0 to 999 seconds).
Mixed Material Fill Time
Enter the mixed material fill time (0 to 999 seconds). It
refers to the amount of time that is required to load
mixed material from the dose valves to the applica-
tor/gun.
Advanced Setup Screen 4
This screen appears only if K-factor Input is set to
“Global” in Option Screen 1, page 32.
K-factor A Meter
Enter the k-factor (cc/pulse) for flow meter A. This is the
amount of material that passes through the flow meter
per pulse (electrical pulse signal).
K-factor B Meter
Enter the k-factor (cc/pulse) for flow meter B.
K-factor Solvent Meter
This field only appears if Solvent Monitor in Configure
Screen 5, page 31, is set to “Meter.” Enter the k-factor
(cc/pulse) for the solvent flow meter.
F
IG. 35. Advanced Setup Screen 3
FIG. 36. Advanced Setup Screen 4