HP (Hewlett-Packard) 232664-006 Network Card User Manual


 
Scripting, command line, and utility options 153
NOTE: The RILOE II is rebooted to apply the changes after MOD_NETWORK_SETTINGS has been closed.
MOD_NETWORK_SETTINGS Runtime Errors
The possible MOD_NETWORK_SETTINGS error messages include:
RIB information is open for read-only access. Write access is required for this operation.
User does not have correct privilege for action.
Logged-in user does not have required privilege for this command.
GET_GLOBAL_SETTINGS
The GET_GLOBAL_SETTINGS command requests the respective RILOE II global settings. For this command
to parse correctly, the command must appear within a RIB_INFO command block, and RIB_INFO MODE
can be set to read or write.
GET_GLOBAL_SETTINGS parameters
None
GET_GLOBAL_SETTINGS runtime errors
None
GET_GLOBAL_SETTINGS return messages
A possible GET_GLOBAL_SETTINGS return message is:
<GET_GLOBAL_SETTINGS
SESSION_TIMEOUT="120"
F8_PROMPT_ENABLED="YES"
HOST_KEYBOARD_ENABLED="YES"
REMOTE_CONSOLE_PORT_STATUS ="ENABLED"
POCKETPC_ACCESS ="NO"
EMS_STATUS ="NO"
BYPASS_POWER_CABLE_REPORTING ="NO"
CIPHER_STRENGTH ="40"
HTTPS_PORT ="443"
HTTP_PORT ="80"
REMOTE_CONSOLE_PORT ="23"
SNMP_ADDRESS_1 =""
SNMP_ADDRESS_2 =""
SNMP_ADDRESS_3 =""
OS_TRAPS ="NO"
RIB_TRAPS ="NO"
CIM_SECURITY_MASK ="MEDIUM"
/>
The following is an example of an unsuccessful request:
<RESPONSE
STATUS = "0x0001"