Scripting, command line, and utility options 157
</RIB_INFO>
</LOGIN>
</RIBCL>
UPDATE_RIB_FIRMWARE parameters
IMAGE_LOCATION takes the full path file name of the firmware upgrade file.
UPDATE_RIB_FIRMWARE runtime errors
The possible UPDATE_RIB_FIRMWARE error messages include:
• RIB information is open for read-only access. Write access is required for this operation.
• Unable to open the firmware image update file.
• Unable to read the firmware image update file.
• The firmware upgrade file size is too big.
• The firmware image file is not valid.
• A valid firmware image has not been loaded.
• The flash process could not be started.
• IMAGE_LOCATION must not be blank.
• User does not have correct privilege for action. CONFIG_ILO_PRIV required.
GET_FW_VERSION
The GET_FW_VERSION command requests the respective RILOE II firmware information. For this
command to parse correctly, the command must appear within a RIB_INFO command block, and
RIB_INFO MODE must be set to write. The user must have the configure RILOE II privilege to execute this
command.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RIB_INFO MODE="read">
<GET_FW_VERSION/>
</RIB_INFO>
</LOGIN>
</RIBCL>
GET_FW_VERSION parameters
None
GET_FW_VERSION runtime errors
None
GET_FW_VERSION return messages
The following information is returned within the response:
<GET_FW_VERSION
FIRMWARE_VERSION = <firmware version>