Scripting, command line, and utility options 155
0 = No Change
1 = Disabled
2 = Automatic
3 = Enabled
In the Automatic setting, the Remote Console port is enabled only when a Remote Console session through
a browser is in progress, and is disabled otherwise.
POCKETPC_ACCESS determines if the PocketPC access is allowed. The possible values are "Yes" or
"No."
REMOTE_CONSOLE_ENCRYPTION determines if Remote Console Data Encryption is enabled or
disabled. The possible values are "Yes" and "No."
CIPHER_STRENGTH determines the SSL encryption strength. The possible values are "40" and "128,"
which enable 40-bit and 128-bit encryption respectively.
HTTPS_PORT—Specifies the HTTPS (SSL) port number for the RILOE II. If this value is changed, the RILOE II
must be reset.
HTTP_PORT—Specifies the HTTP port number for the RILOE II. If this value is changed, the RILOE II must be
reset.
REMOTE_CONSOLE_PORT—This parameter specifies the Remote Console port for the RILOE II. The RILOE
II needs to be reset if this value is changed.
SNMP_ADDRESS_1, SNMP_ADDRESS_2, and SNMP_ADDRESS_3 are the addresses that receive traps
sent to the user. Each of these parameters can be any valid IP address or DNS name and has a maximum
value of 50 characters.
SNMP Traps send trap information according to the value, if the tag is set with a value attribute. If the tag
is not set, "No" is assumed, and traps are not sent.
OS_TRAPS indicates that the user should receive SNMP traps that are generated by the operating system.
The possible values are "Yes" and "No." If the value is not set, then the default "No" is assumed, and
traps are not sent.
RIB_TRAPS indicates that the user should receive SNMP traps that are generated by the RIB. The possible
values are "Yes" and "No." If the value is not set, then the default "No" is assumed, and traps are not
sent.
BYPASS_POWER_CABLE_REPORTING determines how the external power cable status is reported. The
possible values are "Yes" and "No."
The value of "Yes" causes the RILOE II board to report to the operating system that the external
power cable is connected irrespective of the actual status. This will cause Insight Manager 7 to
report a green status for the board if the external cable is not connected, barring other status
problems.
The value of "No" will cause the board to report the true status of the external power connector. This will
cause RILOE II to report the status of the board as degraded if the external connector is not connected.
CIM_SECURITY_MASK accepts an integer between 0 and 4. The possible values are:
0—No change
1—None (No data is returned to Systems Insight Manager.)
2—Low (Name and status data are returned. Associations are present if SNMP pass-through is
supported. If not, the server and management processor are separate entities in the device list.)
3—Medium (RILOE II and server associations are present but the summary page contains less detail
than at high security.)
4—High (Associations are present and all data is present on the summary page.)