HP (Hewlett-Packard) 24SII Printer User Manual


 
A.5 MODULAR CABLING USING M24SII-V06A I/O
MODULE
COMPUTER INTERFACE
To interface your computers or terminals to the Model 24SII using
EIA-232
protocol, refer to the RJ-45 adapter drawings below. Refer to
Figure 13
if your computers or terminals have DB-25 male connectors
(most IBM XT and PS/2 type computers). Refer to
Figure 14
if your
computers have DE-9 male connectors (IBM AT type computers).
1
2
3
4
5
6
7
8
20
8
7
6
5
4
3
2
RTS
RX
DCD
DTR
GND
DSR
TX
CTS
FEMALE DB-25
RJ-45
BLUE
ORANGE
BLACK
RED
GREEN
YELLOW
BROWN
GRAY
Figure 13
RJ-45 FEMALE DE-9
DTR
DCD
GND
DSR
CTS
RTS
RX
TX
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
1
GRAY
BROWN
YELLOW
GREEN
RED
BLACK
ORANGE
BLUE
Figure 14