HP (Hewlett-Packard) 695523-005 Server User Manual


 
Enclosure management commands 126
Spare Part Number: XXXXXX-001
Product Ver:
Diagnostic Status:
Internal Data OK
Device Failure OK
Power Cord OK
SHOW ENCLOSURE STATUS
Command:
SHOW ENCLOSURE STATUS
Description:
Displays the basic health and status of the enclosure subsystem
Access level/Bay level:
All
Restrictions:
None
Example:
OA-0018FE27577F> SHOW ENCLOSURE STATUS
Enclosure:
Status: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Onboard Administrator:
Status: OK
Power Subsystem:
Status: OK
Power Mode: Not Redundant
Power Capacity: 3600 Watts DC
Power Available: 2685 Watts DC
Present Power: 463 Watts AC
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 6/6/5
Fan 1: 9497 RPM (53%)
Fan 2: 7342 RPM (41%)
Fan 3: 9493 RPM (53%)
Fan 4: 9495 RPM (53%)
Fan 5: 7343 RPM (41%)
Fan 6: 9508 RPM (53%)
SHOW ENCLOSURE TEMP
Command:
SHOW ENCLOSURE TEMP
Description:
Displays the highest ambient temperature being reported by the installed blade devices. If no blade
devices are installed, displays the temperature of the OA module as an approximation of the ambient
temperature.