HP (Hewlett-Packard) 695523-005 Server User Manual


 
Enclosure management commands 134
Onboard Administrator USB setting = FRONT
SHOW POWER
Command:
SHOW POWER
Description:
Displays the current power configuration
Access level/Bay level:
All
Restrictions:
None
Example:
OA-0018FE27577F> SHOW POWER
Power Mode: Not Redundant
Dynamic Power: Enabled
Set Power Limit: Not Set
Power Capacity: 3600 Watts DC
Power Available: 2685 Watts DC
Power Allocated: 915 Watts DC
Present Power: 476 Watts AC
Power Limit: 4378 Watts AC
SHOW SYSLOG
Command:
SHOW SYSLOG {SERVER <bay number> | ILO <bay number> | ENCLOSURE | OA <bay
number> | HISTORY | SETTINGS}
Description:
Displays the syslog of the enclosure with 22 lines per screen. To quit the command, enter q. Any other
key shows the next screen, if there is more information to display.
Access level/Bay level:
Bay specific
All
Restrictions:
You must have access to the specified bay.
Example:
OA-0016355E560A> SHOW SYSLOG SERVER
Retrieving Server syslog(s) ...
Server 1 Syslog:
<EVENT_LOG DESCRIPTION="Integrated Management Log">
<EVENT
SEVERITY="Informational"
CLASS="Maintenance"
LAST_UPDATE="02/12/2007 18:01"
INITIAL_UPDATE="02/12/2007 18:01"