HP (Hewlett-Packard) DL580 Server User Manual


 
Removal and replacement procedures 32
IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error
message is displayed when the server is powered up, indicating that the battery pack is temporarily
disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries
and enables the battery pack. This process might take up to four hours. During this time, the cache module
functions properly, but without the performance advantage of the battery pack.
NOTE: The data protection and the time limit also apply if a power outage occurs. When power is restored
to the system, an initialization process writes the preserved data to the hard drives.
Removing the BBWC cache module
1. Power down the server (on page 16).
2. Extend or remove the server from the rack ("Remove the server from the rack" on page 16).
3. Remove the access panel ("Removing the access panel" on page 17).
4. Remove the system cage ("Removing the system cage" on page 17).
CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery
pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.
CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before
unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the
cable from the cache module. The cache module is backing up data, and data is lost if the cable is
detached.
5. Open the latches, and remove the BBWC cache module.
6. Disconnect the cable from the cache module.
To replace the component, reverse the removal procedure.
Removing the system board
CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. If you
believe the system board requires replacement, contact HP Technical Support before proceeding.