HP (Hewlett-Packard) E1459A Network Router User Manual


 
Installing and Configuring the HP E1459A 17
Input Data Capture The state of any channel, within any channel group, may be captured for
subsequent processing (as data) by an externally sourced capture clock
(XTRIG0N - XTRIG3N, the external trigger inputs for each port). Data
channels may be interspersed among all 64 channel inputs, but the user is
cautioned to ensure that all setup criteria and clock sources coincide with
requirements for synchronization. (Each channel group shares a common
capture clock which may not necessarily be synchronous with an external
capture clock of some other channel group.)
If enabled, each register FPGA will post a "Data Available Marker" to the
control FPGA on the occurrence of a corresponding capture clock. Data
Available Markers are cleared by a read of the corresponding "Channel Data
Register." (The static state of these markers may be tested via the "Data
Available Register.") Capture clocks which occur concurrently with a
"register read/marker clear" cycle, are queued and post- processed on
completion of the present cycle. In that event, the marker bit is forced
inactive for a two clock (16 MHz) period before again being posted to the
control FPGA.
In the "Data Capture Mode", the HP E1459A may be programmed to
generate an interrupt on the occurrence of an external capture clock, or an
internal 1.0 MHz sample clock may be selected to allow the state of the data
channels to be tested in the absence of a capture clock. Capture clock
selection (internal/external) is controlled by bit 1 of the Command Register
Word.
Caution A potential hazard exists if software were to improperly
program the HP E1459A to post data-capture IRQ's with the
internally selected 1.0 MHz clock source. In this situation, a
DAV interrupt would be posted each microsecond (if software
were able to service at that rate), and would cause software to
continuously vector to interrupt service upon each "return from
service." Therefore, the HP E1459A should never be
programmed to generate DAV interrupts with the internal clock
source selected.
In the HP E1459A the Data Ready Marker is guaranteed to be
cleared when the clock source is switched from internal to
external. Therefore, any capture clock which occurs within the
internal/external clock selection interval will not post a marker
to the control FPGA and will be lost.