HP (Hewlett-Packard) E1459A Network Router User Manual


 
HP E1459A SCPI Command Reference 63
STATus:OPERation:ENABle?
Returns the value of the OPERation Status Enable Register as a signed 16 bit integer.
Parameters None
Comments The only defined bit is bit 9 which is the summary of the Data Available and
Edge Status for Ports 0, 1, 2, and 3. See Figure 3-1.
STATus:OPERation[:EVENt]?
Returns the value of the OPERation Status Event Register as a signed 16 bit integer
and then clears the register to 0.
Parameters None
Comments The only bit in the OPERation Status Register used by the HP E1459A is bit 9
(decimal weight 512) which contains the summary of the Operation Status Port
Register. This is a destructive read so that all register bits are cleared after the
read is executed.
*RST does not affect the contents of the Status Operation Event Register.
*CLS clears the contents of the Status Operation Event Register.
STAT:PRESet does not affect the contents of the Status Operation Event
Register but does disable reporting the summary of this register in the Status
Byte Register (STB?).
STATus:OPERation:PSUMmary:CONDition?
Returns the value of the OPERation Status Port Summary Condition Register as a
signed 16 bit integer.
Parameters None
Comments Bits 0 through 3 reflect Data Available on Ports 0 through 3 respectively; bits 4
through 7 reflect edge events on Ports 0 through 3 respectively. See Figure 3-1.
Note: THis command does not clear the Port summary Condition Register. The
register is cleared only by removing the the condition itself. For example,
MEAS:DIG:DATA0 will clear Bit 0 if it was set.
*RST clears all Status Operation Port Conditions.
*CLS does not affect the contents of the Status Operation Port Register
Conditions.
The STAT:PRESet command does not affect the Status Operation Port Register
contents.