HP (Hewlett-Packard) FC 1GB/2GB SWITCH 16B Switch User Manual


 
2-16 HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference
Installing and Configuring the HP Surestore FC 1Gb/2Gb Switch 16B
2
a. To change the port topology for controller 1 enter the following command, selecting
4 for Direct Fabric Attach:
vfpmgr -t 4 -c 1
When prompted to reset, enter no.
b. To change the port topology for controller 2 enter the following
command, using the same topology value used for controller 1:
vfpmgr -t 4 -c 2
When prompted to reset, enter no if additional settings must be changed. If all
changes have been made, enter
yes to reset the array.
Private Loop Devices
To work with private loop devices such as the FC 60, the FC 10, or the SCSI bridge FC 4/
2, set the FC 16B switch port as an L_PORT. See the telnet command
portCfgLport.