HP (Hewlett-Packard) FC 1GB/2GB SWITCH 16B Switch User Manual


 
HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference Guide 3-5
Operating the HP Surestore FC 1Gb/2Gb Switch 16B
3
Table 3-2 describes the LEDs on the power supply side of the switch.
Interpreting POST Results
Each time the switch is powered on or reset, the switch automatically performs POST, a one minute
system check during which the port status LEDs flash different colors.
To determine whether POST completed without errors, verify that all LEDs return to a normal state
after POST is complete. If one or more LEDs do not return to a normal state, and this is not due to
the switch being set to beacon, see Interpreting LED Activity on page 3-1 (for more information
about beaconing, refer to the Fabric OS Procedures Guide).
Note: If the switch prompt does not display when POST completes, POST was not successfully
completed and the switch should be returned to your HP account representative for repair.
Any errors detected during POST are written to the system log, accessible through the errShow
command. For more information about error messages, refer to the Fabric OS Reference.
Table 3-2 Power Supply Side LED Patterns During Normal Operation
Location
of LED
Purpose
of LED
Color of LED Status of Hardware Recommended
Action
On each
power
supply
Indicates
status of
related
power
supply
No light Power supply is not
providing power.
Verify power supply is
on and power cable is
connected to a valid
power source.
Steady green Power supply is providing
power.
No action required.
Center of
power
supply
side
Indicates
switch
status
No light Either the switch is off, or
boot is not complete, or
boot has failed.
Verify that the switch
is on and boot has had
time to complete. If
there is still no light,
contact your HP
account representative.
Steady green Switch is on and boot has
successfully completed.
No action required.
Steady yellow Diagnostic command is in
progress, or one or more
ports are faulty.
If no diagnostic tests
are running, check the
Port Status LEDs for
fault indicators.
Slow-flashing
yellow
Diagnostic failure on one or
more ports.
Errors may be listed in
the error log. Refer to
the Fabric OS
Procedures Guide for
more information.