HP (Hewlett-Packard) GbE2 Switch User Manual


 
Runtime switching software default settings 41
Table 12 Switch A and Switch B: general default settings
Setting Value
Serial Port Data Bit 8
Serial Port Parity Bit None
Serial Port Stop Bit 1
Serial Port Flow Control None
Default VLAN Default VLAN (VID=1) with all ports
assigned including CPU, STG=1
NTP State Disabled
NTP Server 0.0.0.0
NTP Resync Interval 720 minutes
GMT Timezone Offset -06:00
Daylight Savings Time State Disabled
System Up Time 0 days 00 :00 :00
Current Time RTC or NTP (00 :00 :00)
Date None
Syslog Host 0.0.0.0
Syslog Host 2 0.0.0.0
Syslog Host Severity 7
Syslog Host 2 Severity 7
Syslog Console Output Disabled
Log console—Enabled
system—Enabled
mgmt—Enabled
cli—Enabled
stp—Enabled
vlan—Enabled
ssh—Enabled
ntp—Enabled
ip—Enabled
web—Enabled
RSA Server Key Autogen Interval 0
RSA Server Key Autogen Disabled
SSH Server On
SCP-only Administrator Password admin
SSH Server Port 22
SCP Apply and Save Disabled
RADIUS Server Off
RADIUS Secret None
Primary RADIUS Server 0.0.0.0
Secondary RADIUS Server 0.0.0.0
RADIUS Server Port 1645
RADIUS Server Retries 3